Effect of Vulcanizing System and Antioxidant System on Aged Tensile Properties of Microptic Gloves

dc.contributor.authorEkanayake, E.A.S.L.
dc.date.accessioned2021-05-17T07:53:10Z
dc.date.available2021-05-17T07:53:10Z
dc.date.issued2014
dc.description.abstractMicrOptic glove is a powder free surgical glove which is made out of the natural rubber latex. Thin nature of MicrOptic glove facilitate exceptional dexterity and tactile sensitivity and at the same time providing strength and barrier protection. The aged tensile properties of the glove cannot be maintained in a stable level due to the thin nature of the glove. As stated in the literature, aging properties can be improved through the adequate selection of vulcanizing system and the antioxidant system for the vulcanizate. Therefore, a study was conducted to disclose the effect of vulcanizing system, antioxidant system and their combined effect on aged tensile properties of MicrOptic glove. 0.5 pphr elementary sulphur, 0.25 pphr elementary sulphur with 0.5 pphr sulphur donor compound and 0.25 pphr elementary sulphur with 1.0 pphr sulphur donor compound were utilized as three different vulcanizing systems in MicrOptic formula. Correspondingly 1.5 pphr primary antioxidant, 1.0 pphr primary antioxidant with 0.25 pphr secondary antioxidant and 1.0 pphr primary antioxidant with 0.5 pphr secondary antioxidant were utilized as three different antioxidant systems in MicrOptic formula. Apropos to the treatment combinations, nine trials were carried out with three replicates. One replicate consisted of 13 test pieces. The Aged tensile properties (force at break, elongation at break and 500 % modulus) were tested for all treatment combinations. The study was disclosed that the effect of vulcanizing system and the combine effect of the vulcanizing system and the antioxidant system significantly affect on the aged tensile properties of MicrOptic glove. 0.25 pphr elementary sulphur with 1.0 pphr sulphur donor compound and 1.0 pphr primary antioxidant with 0.5 pphr secondary antioxidant combination offered the better performance for the aged tensile properties of the MicrOptic glove. Moreover 0.25 pphr elementary sulphur with 0.5 pphr sulphur donor compound and 1.5 pphr primary antioxidant combination can be applied for the current MicrOptic manufacturing process with the cost effective way while satisfying the requirements of EN 455-2:2000 standards. Key words: Aged tensile properties, Antioxidant, system, MicrOptic glove, Vulcanizing systemen_US
dc.identifier.otherUWU/PLT/10/0012
dc.identifier.urihttp://www.erepo.lib.uwu.ac.lk/handle/123456789/6734
dc.language.isoenen_US
dc.publisherUva Wellassa University of Sri Lankaen_US
dc.relation.ispartofseries;UWU/PLT/10/0012
dc.subjectPalm and Latex Technology and Value Addition Degree Programme ( PLT)en_US
dc.titleEffect of Vulcanizing System and Antioxidant System on Aged Tensile Properties of Microptic Glovesen_US
dc.title.alternativeResearch Article – PLT 2014en_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
UWULD PLT 10 0012-18042019103536.pdf
Size:
8.04 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: