General Characteristics of Wastewater and Effectiveness of Existing Treatment Methods in Hospitals with Special Reference to Uva Province

dc.contributor.authorKumara, A.M.I.U.
dc.contributor.authorYoung, S.M.
dc.contributor.authorAmaraweera, T.H.N.G.
dc.contributor.authorYapa, Y.M.S.S.
dc.date.accessioned2019-07-23T06:59:56Z
dc.date.available2019-07-23T06:59:56Z
dc.date.issued2018
dc.description.abstractHospital wastewater has gained a significant attention due to release of untreated toxic chemicals and pathogens to the environment. Although, there are some treatment facilities in hospitals, most of the wastes are partially or untreated before releasing to the environment. This study thus focuses to asses and gives suggestions to improve an existing treatment plant for better function and performance and investigate a hospital that does not have a treatment plant to give suggestions. Wastewaters from Badulla hospital (n=5) and Bibile hospital (n=4) were collected weekly over a period of three weeks (total n=27) where physical (n=5), chemical (n=12) and biological (n=1) parameters were measured. The water quality after the trickling filter in Badulla hospital shows a clear drop for Five-Day Biochemical Oxygen Demand (BOD5), Total Suspended Solids and pH. The BOD5, Chemical Oxygen Demand, Total Suspended Solids and PO43- of the waters ranged between 21-108 mg L-1, 130-290 mg L-1, 290-904 mg L-1 and 11.84-16.39 mg L-1 respectively and are much higher than Central Environmental Authority standards in Sri Lanka. There were no microbes detected after the Ultraviolet (UV) plant and perhaps due to heavy use of Chlorine in spite of the UV treatment. In Bibile hospital, all discharged water outlets are open to the environment. The BOD5, PO43- and NO3- of discharged water varies within 8-98 mg L-1, 3.77-8.16 mg L-1 and 0.8014.60 mg L-1 and are much higher than accepted standards. The treatment plant at Badulla hospital is unsatisfactory to meet the requirements of the accepted standards. Thus, the treatment process of the trickling filter needs improvements in where the rock particles have to be replaced with rock particles in a varying size order. The results indicate that a treatment plant is required for the Bibile hospital with immediate effect.en_US
dc.identifier.isbn9789550481194
dc.identifier.urihttp://www.erepo.lib.uwu.ac.lk/handle/123456789/1549
dc.language.isoenen_US
dc.publisherUva Wellassa University of Sri Lankaen_US
dc.subjectEnvironmental Scienceen_US
dc.subjectEnvironmental Engineeringen_US
dc.subjectGeochemistryen_US
dc.subjectEcologyen_US
dc.titleGeneral Characteristics of Wastewater and Effectiveness of Existing Treatment Methods in Hospitals with Special Reference to Uva Provinceen_US
dc.title.alternativeInternational Research Conference 2018en_US
dc.typeOtheren_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
225-2018-General Characteristics of Wastewater and Effectiveness of Existing .pdf
Size:
115.66 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: